Preci Chuck Accuracy Chart
Testing Results in
mm
Tolerance as per I.S. 2876-78
Grade
OD and face
Ø150 - Ø250
0.05
0.02
Ø330 - Ø400
0.08
0.03
Run out on test mandrel held in jaws
Ø150 - Ø250
0.075
0.015
Ø330
0.075
0.02
Ø400
0.075
0.03
Concentricity face runout over disc runout
Ø150 - Ø250
0.075
0.01
Ø330 - Ø400
0.075
0.02